Hp Serial Port Adapter Pinout

Posted by admin
Hp Serial Port Adapter Pinout Average ratng: 7,8/10 9769 votes
Pinout

Not a whole lot to write up on this one.Right click in channels list, hit add channel. At the bottom of the list (under external inputs) you'll see 'serial port'. Find your WB and unit in the list.

Adobe lightroom 4 serial code. Double click it, and you're done.Connect WB to serial port and Scanner will automatically figure out what port it's on, no config neededSerial inputs are a bit hit or miss. Seems the AEM one works pretty well, Innovate is hit or miss last time I tried.If the channel disappears or is blank when you start logging then it isn't working, either from not being connected properly or from the WB manufacturer not following their own serial standards. Not a whole lot to write up on this one.Right click in channels list, hit add channel. At the bottom of the list (under external inputs) you'll see 'serial port'. Find your WB and unit in the list. Double click it, and you're done.Connect WB to serial port and Scanner will automatically figure out what port it's on, no config neededSerial inputs are a bit hit or miss.

Data protocol should be defined in their users manual.i.e Innovate. Or AEM.Ed MThankyou for that. For some reason i thought i looked at the AEM manual but didnt see that info.Based on the fact the AEM unit only outputs the AFR, i figured i would go with that.from the manual The format is simply the value followed by acarriage return and line feed, e.g. '14.7rn'which is how I have set the arduino to output, but for some reason still not clicking with the scanner.I am sleepy, so will need to have a look tomorrow. I am sure it is something silly.

Perhaps the info in the 4110 manual is better. Sorry it didn't copy and paste the best:-) Google the maunal for a better look.Serial OutputThe serial output can be used for data logging when an EFI system is not accessible. To run thedata stream, a RS-232 (DB-9) Female Receptacle shall be purchased.123456789Figure 5. Wire View of RS-232 (DB-9) Male PlugTwo wires need to be connected to a RS-232 serial port.

Serial Port Card

The BLUE wire from the AEM UEGOGauge shall be connected to Pin #2 (RX) on the serial port for receiving data. Pin # 5 (GND) onthe serial port shall be grounded. If a standard 9-pin serial cable is to be cut instead, the (RX)wire is typically RED and the (GND) wire is typically GREEN. However, this should be confirmedwith a continuity tester before attempting.

(Figure 5) Use HyperTerminal for testing the data stream. This software is found on most PCs prior toWindows 7; other operating systems will require locating alternative terminal software such asTeraTerm or RealTerm. To find HyperTerminal go to: Start All Programs Accessories Communications HyperTerminal. Name the New Connection and click OK. Set the COM portto the one being used and click OK.Bits per Second = 9600Data Bits = 8Parity = NoneStop Bits = 1Flow Control = Hardware Page 9Verify the settings above and click OK.

When power is supplied to the AEM UEGO Gauge, AFR(or Lambda) data will be displayed, as shown below. (Figure 6)Ed M. Hi Ed,What you initially linked was definitely helpful!The innovate obvioulsy has more functionality, as does the Zeitronix zt-2, making the serial stream more complicated as a result.Luckily the AEM is only outputting afr data, which makes it far easier to replicate.i think my issue yesterday was the fact i was using the arduino serial monitor to view the stream, and that was impacting the scanner from being able to connect.so, to update the thread, I did it!

I have a MAX232 serial to ttl converter taking the data stream from the zeitronix to the arduino, then the arduino converting that to the format expected by the HP tuners scanner.Works great.the Zeitronix seems to have logged at up to 0.1 leaner than the serial data stream around stoich, and showing richer when leaner. I haven't driven the car, just a quick start and see what happened.As we know a voltage can be interfered with, however a data stream cant.if anyone is after the code i am happy to share it, even though it would be worth $1000 bucks due to my time wasted! Not a whole lot to write up on this one.Right click in channels list, hit add channel. At the bottom of the list (under external inputs) you'll see 'serial port'. Find your WB and unit in the list.

Double click it, and you're done.Connect WB to serial port and Scanner will automatically figure out what port it's on, no config neededSerial inputs are a bit hit or miss. Seems the AEM one works pretty well, Innovate is hit or miss last time I tried.If the channel disappears or is blank when you start logging then it isn't working, either from not being connected properly or from the WB manufacturer not following their own serial standardsSo if I connect the serial output of my AEM wideband to a serial/usb connector and plug it into my laptop, the HP Tuners software will look for it and find it if I select it in the channels list?

The Hewlett-Packard Company (commonly referred to as HP) or shortened to Hewlett-Packard was an American multinational information technology company. It developed and provided a wide variety of hardware components as well as software and related services to consumers, small- and medium-sized businesses (SMBs) and large enterprises, including customers in the government, health and education sectors. There are 295 pinouts found for various HP devices.A pinout (pin-out) is a cross-reference between the contacts (pins) of an electrical connector and their functions.A short description of connectors used in this equipment is included.Show pinouts for.